IE FC TP STANDARD CABLE GP 4X2, TP-INSTALLATIONS CABLE CAT6 FOR CONNECTING TO IE FC RJ45 PLUG 4X2, AWG24, SOLD BY THE METER, MAX. CONSIGNMENT: 1000 M, MIN. LENGTH ORDERED: 20 M
Order number |
6XV1870-2E |
6XV1878-2A | |
---|---|---|---|
Product type designation |
IE FC TP Standard Cable GP 4x2 (AWG 22) |
IE FC TP Standard Cable GP 4x2 (AWG 24, Type C) | |
Product description |
Standard bus cable (8-core), sold by the meter, unassembled |
Shielded TP installation cable (8-core), sold by the meter, unassembled | |
Suitability for use |
Standard cable with rigid cores for fast, permanent installation |
Standard cable with rigid cores for fast, permanent installation |
|
Cable designation |
2YH (ST) C 4X2X0.64/1.25-100 GN 4x2xAWG22 |
||
Electrical data |
|
|
|
Damping ratio per length |
|
|
|
|
60 dB/km |
58 dB/km |
|
|
190 dB/km |
191 dB/km |
|
|
330 dB/km |
311 dB/km |
|
|
0.343 dB/m |
||
Impedance |
|
|
|
|
100 Ω |
100 Ω |
|
Near-end crosstalk per length |
|
|
|
|
0.453 dB/m |
||
|
383 dB/km |
393 dB/km |
|
|
0.381 dB/m |
||
Transfer impedance per length at 10 MHz |
10 mΩ/m |
20 mΩ/m |
|
Loop resistance per length maximum |
118 Ω/km |
190 Ω/km |
|
Insulation resistance coefficient |
5 000 GΩ·m |
5 000 GΩ·m |
|
Operating voltage |
|
|
|
|
100 V |
100 V |
|
NVP value in percent |
68 % |
66 % |
|
Mechanical data |
|
|
|
Number of electrical cores |
8 |
8 |
|
Design of the shield |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
|
Type of electrical connection FastConnect |
Yes |
Yes |
|
Core diameter |
|
|
|
|
0.64 mm |
||
|
0.51 mm |
||
Outer diameter |
|
|
|
|
0.64 mm |
0.51 mm |
|
|
1.25 mm |
1 mm |
|
|
7.6 mm |
6.1 mm |
|
|
9.6 mm |
8 mm |
|
Symmetrical tolerance of the outer diameter of cable sheath |
0.3 mm |
0.2 mm |
|
Material |
|
|
|
|
PE |
PE |
|
|
PVC |
FRNC |
|
|
PVC |
PVC |
|
Color |
|
|
|
|
white/blue, white/orange, white/green, white/brown |
white-blue/blue, white-orange/orange, white-green/green, white-brown/brown |
|
|
green |
green |
|
Bending radius |
|
|
|
|
38 mm |
24 mm |
|
|
80 mm |
40 mm |
|
Tensile load maximum |
180 N |
100 N |
|
Weight per length |
104 kg/km |
80 kg/km |
|
Permitted ambient conditions |
|
|
|
Ambient temperature |
|
|
|
|
-40 ... +80 °C |
-40 ... +85 °C |
|
|
-40 ... +80 °C |
-40 ... +80 °C |
|
|
-40 ... +80 °C |
-40 ... +80 °C |
|
|
-40 ... +80 °C |
-40 ... +80 °C |
|
Ambient condition for operation |
Temperature range for permanent installation -40 °C to +85 °C |
||
Burning behavior |
flame resistant according to IEC 60332-1 |
flame resistant according to IEC 60332-3-24 (Category C) |
|
Chemical resistance |
|
|
|
|
oil resistant according to IEC 60811-2-1 (4 h / 70°C) |
oil resistant according to IEC 60811-2-1 (4 h / 70°C) |
|
|
Conditional resistance |
Conditional resistance |
|
|
Conditional resistance |
Conditional resistance |
|
Radiological resistance to UV radiation |
resistant |
resistant |
|
Product properties, functions, components general |
|
|
|
Product property |
|
|
|
|
No |
No |
|
|
Yes |
Yes |
|
Cable length for Industrial Ethernet |
|
|
|
|
90 m |
100 m |
|
|
90 m |
100 m |
|
Standards, specifications, approvals |
|
|
|
Certificate of suitability |
|
|
|
|
Yes |
Yes |
|
|
Yes |
Yes |
|
Standard for structured cabling |
Cat6 |
Cat6A |
|
Marine classification association |
|
|
|
|
No |
No |
|
|
No |
No |
|
|
No |
No |
|
|
No |
No |
|
|
No |
No |
|
|
No |
No |
|
|
No |
No |
The 8-core cabling system of SIMATIC NET allows transmission rates of 10/100/1 000 Mbit/s for Ethernet as with the service-independent cabling from the office environment. This permits the transition from the 4-core Industrial Ethernet cabling system to the 8-core cabling system with Gigabit capability.
The IE FC TP Standard Cable GP 4 x 2 (AWG22) must be used in conjunction with the IE FC Modular Outlet and the TP Cords for constructing Industrial Ethernet networks (8-core) up to 100 m.
The IE FC TP Standard Cable GP 4 x 2 (AWG22) must be used in conjunction with the IE FC Modular Outlet and the TP Cords for constructing Industrial Ethernet networks (8-core) up to 100 m.
For direct connection without using patch technology, the IE FC RJ45 Plug 4 x 2 and the IE FC TP Cable 4 x 2 (AWG24) of up to 90 m can be used.
For the construction of Industrial Ethernet networks (8-core) up to 100 m in railway applications (cable is approved for railway applications)
Note:
Further information on the network configuration can be found in the manual for TP and fiber-optic networks.
UL approvals
The IE FC TP cable GP 4 x 2 (AWG22 and AWG24) has the relevant UL / ETL approvals for laying in cable bundles and cable racks according to the specifications of NEC (National Electrical Code) Article 800/725.
The FastConnect (FC) Industrial Ethernet cables IE FC Cable 4 x 2 (AWG22 and AWG24) are designed with radial symmetry and therefore allow the use of the IE FC Stripping Tool. The IE FC RJ45 Modular Outlet and the IE FC RJ45 Plug 4 x 2 can then be connected quickly and easily by means of insulation displacement contacts without the need for special tools.
Cable types
System configuration with IE FC RJ45 Modular Outlet 100 Mbit/s and 1000 Mbit/s
Изделие: 6ES7590-8AA00-0AA0
SIMATIC S7-1500 ЗАПЧАСТЬ - СОЕДИНИТЕЛЬНЫЙ РАЗЪЁМ ДЛЯ ВСЕХ СИСТЕМНЫХ БЛОКОВ ПИТАНИЯ (PS) И БЛОКОВ ПИТАНИЯ (PM), 10 ШТ. В УПАКОВКЕ
Изделие: 6GK1500-0AA10
SIMATIC NET, ТЕРМИНАЛ 12M: ДЛЯ ПОДКЛ. СТАНЦИЙ К СЕТИ PROFIBUS (RS485), ДО 12 МБИТ/С, КОНТАКТЫ ПОД ВИНТ ДЛЯ ПОДКЛ. К ЛИНИИ PROFIBUS, ОТВОД ДЛИНОЙ 1.5 M ДЛЯ ПОДКЛ. PROFIBUS СТАНЦИИ
Изделие: 6ES7902-3AG00-0AA0
SIMATIC S7, КАБЕЛЬ ДЛЯ PTP СОЕДИНЕНИЙ RS422 - RS422, ДВА 15-ПОЛЮСНЫХ ШТЕКЕРА СОЕДИНИТЕЛЕЙ D-ТИПА, ДЛИНА 50M
Изделие: 6ES7511-1AK01-4YB5
СТАРТОВЫЙ НАБОР SIMATIC S7-1500, В СОСТАВЕ: CPU 1511-1 PN, DI 16X24VDC HF, DQ 16X24VDC/0.5A ST, БП PM1507, 24V/3A, ПРОФИЛЬНАЯ ШИНА 160MM, КАРТА ПАМЯТИ SIMATIC MC 4 МБ, ФРОНТАЛЬНЫЙ СОЕДИНИТЕЛЬ, КАБЕЛЬ ETHERNET, ПО STEP 7 V13 PROFESSIONAL ЛИЦЕНЗИЯ TRIAL365, ИНФОРМАЦИОННЫЕ МАТЕРИАЛЫ