Order number |
6XV1870-3QH10 |
6XV1850-2JH10 | |
---|---|---|---|
Product type designation |
IE TP Cord RJ45/RJ45, 4x2 |
IE TP Cord 9/RJ45, 2x2 | |
Product description |
Patch cable, preferred length, preassembled with two RJ45 connectors (10/100/1000/10000MB) |
Patch cable, preferred length, preassembled with one 9-pole D-sub connector and one RJ45 connector | |
Suitability for use |
Easy connection of data terminals to the IE FC cabling system |
Easy connection of data terminals to the IE FC cabling system |
|
Cable designation |
LI 02YSCH 4x2x0,15 PIMF GN FRNC |
LI 02YSCY 2x2x0,15/0,98 PIMF ICCS GN |
|
Cable length |
1 m |
1 m |
|
Electrical data |
|
|
|
Damping ratio per length |
|
|
|
|
86 dB/km |
85 dB/km |
|
|
280 dB/km |
278 dB/km |
|
|
501 dB/km |
500 dB/km |
|
|
735 dB/km |
733 dB/km |
|
Impedance |
|
|
|
|
100 Ω |
100 Ω |
|
|
100 Ω |
100 Ω |
|
Relative symmetrical tolerance |
|
|
|
|
15 % |
15 % |
|
|
10 % |
6 % |
|
Transfer impedance per length at 10 MHz |
10 mΩ/m |
10 mΩ/m |
|
Loop resistance per length maximum |
290 Ω/km |
300 Ω/km |
|
Insulation resistance coefficient |
500 GΩ·m |
500 GΩ·m |
|
NVP value in percent |
80 % |
||
Mechanical data |
|
|
|
Number of electrical cores |
8 |
4 |
|
Design of the shield |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
|
Core diameter |
|
|
|
|
0.5 mm |
0.48 m |
|
Outer diameter |
|
|
|
|
0.5 mm |
0.48 mm |
|
|
1 mm |
0.98 mm |
|
|
6.2 mm |
||
Symmetrical tolerance of the outer diameter of cable sheath |
0.3 mm |
||
Width of cable sheath |
5.8 mm |
||
Symmetrical tolerance of width of cable sheath |
0.2 mm |
||
Thickness of cable sheath |
3.7 mm |
||
Symmetrical tolerance of thickness of cable sheath |
0.2 mm |
||
Material |
|
|
|
|
PE |
PE |
|
|
FRNC |
PVC |
|
Color |
|
|
|
|
white/blue, white/orange, white/green, white/brown |
white/blue, white/orange |
|
|
green |
green |
|
Bending radius |
|
|
|
|
31 mm |
24 mm |
|
|
43.5 mm |
42 mm |
|
Weight per length |
50 kg/km |
32 kg/km |
|
Permitted ambient conditions |
|
|
|
Ambient temperature |
|
|
|
|
-25 ... +80 °C |
-40 ... +70 °C |
|
|
-25 ... +80 °C |
-40 ... +70 °C |
|
|
-25 ... +80 °C |
-40 ... +70 °C |
|
|
-25 ... +80 °C |
-40 ... +70 °C |
|
|
in fixed installation -40°C to 80°C |
||
Burning behavior |
flame resistant according to IEC 60332-1 |
flame resistant according to IEC 60332-1 |
|
Chemical resistance |
|
|
|
|
oil resistant according to IEC 60811-2-1 (4 h / 70°C) |
oil resistant according to IEC 60811-2-1 (4 h / 70°C) |
|
|
Conditional resistance |
Conditional resistance |
|
Protection class IP |
IP20 |
IP20 |
|
Product properties, functions, components general |
|
|
|
Product property |
|
|
|
|
Yes |
No |
|
|
Yes |
Yes |
|
Standards, specifications, approvals |
|
|
|
Certificate of suitability |
|
|
|
|
Yes |
Yes |
|
Standard for structured cabling |
Cat6A |
Cat7 |
|
Marine classification association |
|
|
|
|
No |
No |
|
|
No |
No |
|
|
No |
No |
|
|
No |
No |
|
|
No |
No |
|
|
No |
No |
|
|
No |
No |
Использование ТР кордов для прямого соединения сетевых компонентов
IE TP корд RJ45/RJ45 может быть использован для прямого соединения сетевых компонентов (10/100/1000 Mбит/сек)
TP корд поставляется с заранее установленными соединителями в следующих версиях:
Повышение гибкости кабельных соединений и обеспечение высоких показателей электромагнитной совместимости. Максимальное расстояние между двумя соединяемыми приборами может достигать 10м.
Адаптация кабельных соединений для работы с приборами, оснащенными различными типами интерфейсов.
Изделие: A5E03694109
SITRANS FC070 WITH PCS 7 OP INSTR EN
Изделие: 6ES7392-1AN00-0AA0
S7-300, ТЕРМИНАЛЬНЫЙ БЛОК С ВИНТОВЫМ ПОДКЛЮЧЕНИЕМ ДЛЯ 64-КАНАЛЬНЫХ МОДУЛЕЙ S7-300, 2 ШТУКИ В УПАКОВКЕ
Изделие: 6ES7390-1AF30-0AA0
SIMATIC S7-300, ПРОФИЛЬНАЯ ШИНА S7-300 ДЛИНОЙ 530MM
Изделие: 6FX50.2-2CC11-....
СИГНАЛЬНЫЙ КАБЕЛЬ С РАЗЪЕМАМИ (АБСОЛЮТНЫЙ ДАТЧИК SSI 6FX2001-5) 4X2X0,34 + 4X0,5 C UL/CSA, DESINA MOTION-CONNECT 500 DМАКС. = 9,3 ММ